Configuration Note 4. Configuring AudioCodes E-SBC
Microsoft Lync and XO Technology SIP Trunk 39 AudioCodes Mediant E-SBC
4.3.3 Step 3c: Configure SIP Signaling Interfaces
This step describes how to configure SIP Interfaces. For the interoperability test topology,
an internal and external SIP Interface must be configured for the E-SBC.
To configure SIP Interfaces:
1. Open the SIP Interface Table page (Configuration tab > VoIP menu > Control
Network > SIP Interface Table).
2. Configure a SIP interface for the LAN:
Parameter Value
Index
1
Network Interface
Voice
Application Type
SBC
TLS Port
5067
TCP and UDP
0
SRD
1
3. Configure a SIP interface for the WAN:
Parameter Value
Index
2
Network Interface
WANSP
Application Type
SBC
UDP Port
5060
TCP and TLS
0
SRD
2
The configured SIP Interfaces are shown in the figure below:
Figure 4-10: Configured SIP Interfaces in SIP Interface Table